6 Operation

Selecting the operating mode:
Pressing the PROG key switches to the next program and to manual mode
Manual:
PROG 1-7: If one of the seven programs is selected, the DC 1200 dispenses as long
Set the dispense time:
The dispense time can be selected with the UP and DOWN keys, and set
from 0 . 0 1 - 999 . 9 9 sec .
Activating the Teach-In function:
The Teach-In function is only available in the manual operation mode .
When this function is activated each dispensing activity adds more dispensing time
to the actual interval (and not set back to 0 . 0 0 sec . ) .
Thus you can approach to a dispensing time interval and material amount when
you establish a new dispensing procedure . These value can be saved to one of the
preinstalled programs . To reset the timer to 0 . 0 0 sec . press SAVE and DOWN key at
the same time .
Activating the Cycle mode:
When the device is in cycle mode a single signal starts a continous loop of
dispensing processes . The dispender runs a predefined cycle of exhausting
compressed air and waiting time . (see next topic - IDLE time) . This looping process
can be stopped by sending an other start signal via PURGE key, footswitch or
external signal from I/O-port .
Adjusting the Cycle mode IDLE time (Zyk-Wartez):
When the device is in cycle mode, the IDLE time can be set by using the UP and
DOWN keys . It can be adjusted from 0 . 0 5 to 999 . 9 9 sec .
The main screen shows a countdown of the IDLE time schematic with a shrinking
bar right aside the counter .
In this mode, the dispense time does not get saved and the DC 1200
dispenses as long as the dispense signal is activated by one of the
following:
footswitch / purge key / I/O-start .
After dispensing, the dispense time starts again at 0 . 0 0 sec .
as the value of the dispense time is set for . This dispense cycle is activa-
ted by one of the following: footswitch / purge key / I/O-start .
This mode should be selected, if the rotary valve should always
dispense for the same time .