Herunterladen Inhalt Inhalt Diese Seite drucken

Installation Dcontrolled Entry And Automatic Exit - o&o CDS 1.3 Installations Und Bedienungs

Steuerzentrale
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 49
INSTALLATION D
12.4
This solution is recommended when you want to enter a reserved area in both directions. To enter, transit is allowed by means of a
recognition command while exiting is automatic.
ENTRY
The vehicle approaches
the reserved area.
EXIT
Loops S1 and S2 also have a safety function in that they will not let the device move all the time the vehicle is on top.
DIMENSIONS
- Connect the contact of the coil S1 receiver to input PDM.
- Connect the N.O. contact of the S2 loop receiver to input
OPEN.
- The dimensional values of the loops are only approximate.
*
We suggest installing the O&O "MAK-2" metal mass detector.
CONTROLLED ENTRY AND AUTOMATIC EXIT
PARAMETER DATA



- 32 -
When the vehicle is on loop S1 the
device will move down only after a
recognition command.
If the device is moving back up
and you want to lower it again the
vehicle must be on loop S1 and then
you must activate the recognition
command.
When the vehicle is no longer on
loop S2 the device will move back
up automatically after an adjustable
pause time.
The vehicle approaches the reser-
ved area.
Occupying the coil S2 activates bol-
lard descent.
When the vehicle is no
longer on loop S2 the
device will move back
up automatically after
an adjustable pause
time.
DESCRIPTION

Functioning logic: Automatic

Opening consent and pause time reset

Radio channel 1: Open

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis