The following table gives the 1st level functions and the single settable parameters.
= DEFAULT value set in factory.
Par
Function
Selects the functioning logic.

(see notes after the table)
Close input confi guration

(see notes after the table)

Photocells
Obstacle detection

(for GRIZZLY only)

Warning fl ash

Bollard lights

Buzzer
Resetting default parame-

ters. (see notes after the
table)
Pause time

(expressed in seconds)

Exiting the menu/saving
Description of level 1 parameters

·
: Functioning logic
- Hold-to-run: Close functions active for as long as control buttons are pressed. Open functions activated by pressing and
releasing control buttons. The start command opens once and closes once.
- Semi automatic: The automation works with jog commands, without automatic reclosing. Hence, when fully open, to control
closing you need to act on the start or close command respectively.
- Automatic: The automation works in jogs. When the opening manoeuvre is completed in the standard cycle, automatic reclo-
sing is activated after the pause time set (parameter ).
7.2
PROGRAMMING
1st LEVEL
: Hold-to-run
: Semi automatic
: Automatic
: Standard close input
: Close-when-released input
: The close command acts as a release closing and safety function.
: During closure, it reopens and waits for the photoelectric cell free
commands.
: When closing it reopens; reclosing after 1'' when the photocell is
disengaged
: When closing it reopens; reclosing after 5'' when the photocell is
disengaged
: Disabled
: When closing it stops and waits for commands
: When closing it reopens and waits for commands
: When closing it reopens, reclosing after 5 seconds

: Cover lights fl ashing during movement, cover lights fi xed when the
bollard is opened and closed
: Cover lights fl ashing during movement and with bollard open, cover
lights fi xed when the bollard is closed
: Cover lights always fl ashing
: Cover lights fl ashing during movement and with bollard closed, cover
lights fi xed when the bollard is open
: Buzzer off
: Buzzer on during movement
: No resetting
: Resetting the default parameters.
: Default parameter reset and confi guration of installation type A pa-
rameters (see chapter 12.1)
: Default parameter reset and confi guration of installation type B pa-
rameters (see chapter 12.2)
: Default parameter reset and confi guration of installation type C pa-
rameters (see chapter 12.3)
: Default parameter reset and confi guration of installation type D pa-
rameters (see chapter 12.4)
-
Exit programming and view machine statuses (see notes St automation
statuses display)
- 23 -
= parameter value set during installation: must be indicated if
DEFAULT value is modifi ed.
Settable data








