The following table gives the 1st level functions and the single settable parameters.
= DEFAULT value set in factory.
Par
Function
Selects the functioning logic.
(see notes after the table)
Close input confi guration
(see notes after the table)
Photocells
Obstacle detection
(for GRIZZLY only)
Warning fl ash
Bollard lights
Buzzer
Resetting default parame-
ters. (see notes after the
table)
Pause time
(expressed in seconds)
Exiting the menu/saving
Description of level 1 parameters
·
: Functioning logic
- Hold-to-run: Close functions active for as long as control buttons are pressed. Open functions activated by pressing and
releasing control buttons. The start command opens once and closes once.
- Semi automatic: The automation works with jog commands, without automatic reclosing. Hence, when fully open, to control
closing you need to act on the start or close command respectively.
- Automatic: The automation works in jogs. When the opening manoeuvre is completed in the standard cycle, automatic reclo-
sing is activated after the pause time set (parameter ).
7.2
PROGRAMMING
1st LEVEL
: Hold-to-run
: Semi automatic
: Automatic
: Standard close input
: Close-when-released input
: The close command acts as a release closing and safety function.
: During closure, it reopens and waits for the photoelectric cell free
commands.
: When closing it reopens; reclosing after 1'' when the photocell is
disengaged
: When closing it reopens; reclosing after 5'' when the photocell is
disengaged
: Disabled
: When closing it stops and waits for commands
: When closing it reopens and waits for commands
: When closing it reopens, reclosing after 5 seconds
: Cover lights fl ashing during movement, cover lights fi xed when the
bollard is opened and closed
: Cover lights fl ashing during movement and with bollard open, cover
lights fi xed when the bollard is closed
: Cover lights always fl ashing
: Cover lights fl ashing during movement and with bollard closed, cover
lights fi xed when the bollard is open
: Buzzer off
: Buzzer on during movement
: No resetting
: Resetting the default parameters.
: Default parameter reset and confi guration of installation type A pa-
rameters (see chapter 12.1)
: Default parameter reset and confi guration of installation type B pa-
rameters (see chapter 12.2)
: Default parameter reset and confi guration of installation type C pa-
rameters (see chapter 12.3)
: Default parameter reset and confi guration of installation type D pa-
rameters (see chapter 12.4)
-
Exit programming and view machine statuses (see notes St automation
statuses display)
- 23 -
= parameter value set during installation: must be indicated if
DEFAULT value is modifi ed.
Settable data