Technical Data

Model
Load capacity of main lift
Load capacity of wheel-free lift
Lifting time (2,000 kg)
Lowering time (2,000 kg)
Electrical system
Control voltage
Motor
rpm
Upstream fuse
Connection cable
Protection type
Flow rate
Working pressure ²
Required compressed air
connection
Recommended hydraulic oil
Oil quantity
Floor anchor
Number of anchors
Permissible sound level
Weight
²
The factory-set working pressure is adjusted to the maximum rated power. The pressure relief valve
must not be manipulated. Changing the settings can lead to serious damage.
If the indicated rated load cannot be lifted, please contact our service team.
1.4.1 Technical Data – Play Detector
Type / actuation
Maximum axle load
Actuating force per plate
Speed of movement
Transverse movement
Longitudinal movement
Control voltage
Motor
rpm
Upstream fuse
Connection cable
Protection type
® Copyright ATH-Heinl GmbH & Co. KG, All rights reserved / Misprints and technical changes reserved / As of: 2020-03
ATH Cross Lift 50 Plus
240 bar (max. 300 bar)
Summer (15 °C to 45 °C): HVLP-D 46 (e.g.: Eni PRECIS HVLP-
D)
Winter (under 10 °C): HVLP-D 32 (e.g.: Eni PRECIS HVLP-D)
Bolt anchor: M16 x 180 (e.g. Atrion ABL-W 16-060-180)
Compound anchor: M16 x 190 (e.g. Atrion AVA-W 16-045-190)
80 mm per plate, inverse
50 mm per plate, inverse and parallel
Manufacturer ATH-Heinl GmbH & CO.KG
- 15 -
5,000 kg
4,000 kg
70 s
60 s
3/400 V/50 Hz
DC 24 V
3.5 kW
1375
3 C 16 A
Min. 5 x 2.5 m²
IP 54
4.8 cm³/U
8 bar
Approx. 18 l
16 units
≤ 80 dB
2,840 kg
Hydraulic
2600 kg
8 kN
50 mm/s
3/400 V/50 Hz
1.1 kW
1400
3 C 16 A
Min. 5 x 2.5 m²
IP 54