1.4

Safety instructions

General safety instructions
Read and understand the operating
instructions before operating the
lift.
Modifications of any kind to the
lifting platform are not permitted
1.5

Technical data

Type
Max. Load capacity
Time for lifting process (1200 kg)
Time for lowering (1200 kg)
Electrical system
Motor
Upstream fuse
Protection class
Working pressure
2
Required compressed air connection
Recommended hydraulic oil
Oil quantity
Ground anchoring
Anchor quantity
® Copyright ATH-Heinl GmbH & Co. KG / All rights reserved / Misprints and technical changes reserved
62
Work on electrical components is
only permitted to locally authorized
electricians
Lifting platform must not be
cleaned under running water
ATH Single Lift 12PL
1200 kg
15 s
16 s
3/400V/50Hz
3,0 KW
3 C 16 A
IP 64
115 bar
8 bar
Summer (10° to 45°): H-LPD 32 (e.g.: OEST-H-LPD 32 DD L)
Winter (below 10°): H-LPD 22
Approx. 10 l
Anchor rod M16x250, W-VD-A/S
in combination with
Injection Mortar Allrounder WIT-VM 250
6 pieces
Release date: 02.05.2023 / Product manufacturer ATH-Heinl GmbH & Co. KG
Leave the danger zone when
lowering the lifting platform
Do not use any paint-dissolving or
highly aggressive cleaning agents