Concrete quality:
Concrete curing time:
Serious damage to property and injury to persons may be caused by flooring that does not meet
the requirements.
Do not install the scissors on asphalt or soft screed.
There cannot be any expansion joints or cracks that may interrupt the continuity of the
reinforcement.
The operator must check the load capacity of suspended ceilings.
The lift must not be installed in damp, wet or potentially explosive areas. The lift must also be
installed indoors and may not be installed outdoors.
Assembly
1. Setting up and aligning the pairs of scissors
a. FOR UNDERFLOOR ASSEMBLY:
Position both pairs of scissors in the pit provided and place the control box on the surface
intended for this purpose.
FOR ELEVATED ASSEMBLY:
Position both pairs of scissors parallel to one another and place the control box on the surface
intended for this purpose, as detailed in the technical data section. Before fixing with dowels,
ensure that both scissors are aligned and, if necessary, adjust using washers or plates.
2. Install hydraulic hoses
In order to attach the hydraulic hoses, it is advisable to lift the two pairs of scissors up to
the first catch position using a suitable tool
a. Open the front cover of the control box.
b. Install the hydraulic hose(s) as shown below.
c. Connect hydraulic hoses and overflow oil lines to the cylinders
as shown.
Tighten all hydraulic connections.
3. Hydraulic oil
Fill hydraulic oil up to the mark on the dipstick.
Only use the oils specified in Technical Data for this purpose.
® Copyright ATH-Heinl GmbH & Co. KG, All rights reserved / Misprints and technical changes reserved / As of: 2020-03