5.2 Operational Readiness when Switching On
The sine and cosine signals are immediately available after
switching on the voltage supply.
Wait at least 150 ms until the encoder is ready for operation,
that is to say until the interfaces are ready for communication.
The encoder will communicate with the outside through the
digital interface only after this period.
Wait at least 200 ms until the encoder is ready for operation,
that is to say until the interfaces are ready for communication.
The encoder will communicate with the outside through the
digital interface only after this period.

6 Maintenance

In harsh environments, we recommend regular inspections
for firm seating and possible damages at the device. Repair
work may only be carried out by the manufacturer, see
chapter Contact [} 27].
Prior to the work
• Switch off the power supply and secure it against switching
on again.
• Then disconnect the power supply lines physically.
• Remove operating and auxiliary materials and remaining
processing materials from the measuring system.
6.1 Disassembly
To dismount the device, proceed in the reverse order of the
assembly, see Electrical Installation [} 22] and
Mechanical Installation [} 18].
BA Sendix® S3674 / S3684 - R60071.0009 - 03
6.2 Reassembly
Reassembling the device is only permitted under the follow-
ing conditions:
• The device is not damaged.
• The screws can be newly secured against loosening.
• All safety instructions of chapter Installation [} 18] can be
complied with.
• All assembly steps described in chapter Installation [} 18]
can be performed.
7 Disposal
Always dispose of unusable or irreparable devices in an en-
vironmentally sound manner, according to the country-spe-
cific provisions and in compliance with the waste disposal
regulations in force. We will be glad to help you dispose of
the devices, see chapter Contacts [} 27].
Environmental damage in case of incorrect disposal
Electrical waste, electronic components, lubricants and other
auxiliary materials are subject to hazardous waste treatment.
Problem substances may only be disposed of by licensed
specialist companies.
Dispose of disassembled device components as follows:
• Metal components in the scrap metal.
• Electronic components in the electrical waste.
• Plastic parts in a recycling center.