Procedure in the event of soiling
Clean and degrease the encoder shaft and the drive shaft be-
fore installation.
Tools
For assembly, use only checked and calibrated tools subjec-
ted to a quality system.
Screws and screwed connections
Unless otherwise specified, a friction coefficient of 0.14 is re-
quired for all screwed connections. Unless otherwise spe-
cified, a strength class of 8.8 (metric) or grade 5 (imperial) is
required for all screws.
4.1.1.1 Assembly Instructions for Tapered Shaft
Encoders
a) Block the drive shaft for the assembly.
b) Tighten the fastening screw of the tapered shaft.
c) Comply with the maximum permissible shaft offset.
d) Screw the stator coupling or the torque stop without pre-
load on the drive flange.
BA Sendix® S3674 / S3684 - R60071.0009 - 03
NOTICE
NOTICE
4.1.2 Dimensions and Mounting Steps
Dimensions
The technical drawing with complete dimensioning can be
found in the data sheets of the corresponding variant of the
device, for special versions in the.corresponding customer
drawing of the product.
The illustrations below only show a selection of examples. All
values without unit in the picture are given in mm [inch].
In order to simplify the drawings and information, unless oth-
erwise specified, the general tolerances with tolerance class
m (medium) according to ISO 2768-1 apply.
4.1.2.1 Tapered Shaft Encoder
Flange type 1 with stator coupling, ø 38
SW 2.5, tightening torque typ. 1 Nm [8.85 lbf-in]
NOTICE
173165579