Herunterladen Inhalt Inhalt Diese Seite drucken

Installation; Preparing For Surface Mounting - Sentiotec Is1-Serie Montage- Und Gebrauchsanweisung

Infrarotsteuerung
Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

Installation instructions, only for experts

4. Installation

The infrared control unit can either be surface-mounted or recess mounted.

4.1. Preparing for surface mounting

To mount the control unit on a surface, you need to make cable bushings in the
cabin wall. Refer to the following figure for the positions.
17,5
► Caution: If the cable is fed down-
wards through the cable shaft 7, the
sensor cable must be fitted with ad-
ditional protective insulation.
Downloaded from
www.Manualslib.com
49
34
49
65
80,5
WORLD OF WELLNESS
manuals search engine
1
7
2 3 4 5 6
1 Sensor cable outlet
2 Mains power line
3 Heater/foils outlet
4 Free
5 Free
6 Light outlet
7 Cable shaft
p. 8/22

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

P-is1-tIs1Is1 p-is1-t

Inhaltsverzeichnis