Installation instructions, only for experts
7. Adjusting the heating time limit
The heating time limit for the control unit is set at the factory to 99 minutes. This
can be extended up to 24 hours by setting the jumper as described below. The
jumper set is available as an accessory under the order number O-JUMP.
N
U
N
Downloaded from
www.Manualslib.com
Heating time settings can only be made to the exact minute for operating
times of up to 99 minutes. From 99 minutes to 9.9 hours, the operating
time can be set with a precision of 0.1 of an hours (6 minutes). After this,
only in 1 hour increments.
ATTENTION!
For domestic use, the heating time limit may be extended to a maximum
of 6 hours. The provisions of EN 60335-2-53 must be observed for heat-
ing time limits of more than 6 hours.
WORLD OF WELLNESS
manuals search engine
Operating time
JP3
99 minutes
6 hours
JP1
12 hours
JP2
24 hours
p. 16/22
Jumper
none
JP1
JP2
JP1 + JP2