W W a a r r n n i i n n g g / / C C a a u u t t i i o o n n / / N N o o t t e e D D e e f f i i n n i i t t i i o o n n
The words W W A A R R N N I I N N G G , C C A A U U T T I I O O N N , and N N O O T T E E carry special meanings and should be carefully reviewed.
W W A A R R N N I I N N G G
Alerts the reader about a situation which, if not avoided, could result in death or serious injury. It may also describe
potential serious adverse reactions and safety hazards.
C C A A U U T T I I O O N N
Alerts the reader of a potentially hazardous situation which, if not avoided, may result in minor or moderate injury to the
user or patient or damage to the product or other property. This includes special care necessary for the safe and effective
use of the device and the care necessary to avoid damage to a device that may occur as a result of use or misuse.
N N o o t t e e - - Provides special information to make maintenance easier or important instructions clearer.
S S u u m m m m a a r r y y o o f f s s a a f f e e t t y y p p r r e e c c a a u u t t i i o o n n s s
Always read and strictly follow the warnings and cautions listed on this page. Service only by qualified personnel.
W W A A R R N N I I N N G G
• Always secure the support surface to the bed frame to prevent the shifting of the product while in use.
• Always inspect for foreign objects between the support surface and the bed frame. Foreign objects may cause the
support surface to slide on the support platform.
• Do not use the support surface on a larger or smaller bed frame that does not fit the width, length, or thickness. This is to
avoid the risk of the support surface sliding, patient injury, or interference with moving parts of the bed.
• Do not use the support surface when gaps are present. The risk of entrapment can develop when the support surface is
placed on incompatible bed frames.
• Always plug the power cord into the bed auxiliary outlet or a grounded power respectable. Do not use an extension cord.
• Do not touch patients and the AST socket on the pump at the same time.
• Always secure the pump to the bed frame to prevent the shifting of the product while in use.
• Always check the product before use to make sure there are no broken parts. If the product is damaged call technical
support.
• Always make sure that you do not exceed the safe working load of the bed frame before you mount the pump.
• Always connect the AST cable to the AST socket on the pump to avoid the risk of electrical shock.
• Do not use in the presence of flammable anesthetics, nitrous oxide, or oxygen-rich environments. Risk of explosion can
result.
• Do not expose this product to liquids while powered as this could result in a severe electrical hazard.
• This product radiates radio frequency energy. If not setup and used in accordance with the instructions, may cause
harmful interference to other devices in the vicinity.
• Always check patient's skin regularly. Consult a physician if erythema or skin breakdown occurs. Serious injury could
result if the patient's skin condition is left untreated.
• Do not use this product with an overlay. Patient stability and siderail coverage may be compromised.
• Always consider the use of siderails. The safe use of the support surface is maximized when used in conjunction with
siderails. There may be an increased risk of falls when siderails are not present. Serious injury or death can result from
the use (potential entrapment) or non-use (potential patient falls) of siderails or other restraints. Consider local policies
regarding the use of siderails. The physician, operator, or responsible parties should determine whether and how to use
siderails based on each patient's individual needs.
• Always use extra caution with a patient at risk of a fall (such as agitated or confused) to help reduce the likelihood of a
fall.
• Do not use the support surface as a transfer device.
• Do not use the support surface handles to lift or move the support surface with a patient on board.
• Do not stick needles or other sharp objects into a support surface through the support surface cover. Holes may allow
fluids to enter the inside (inner core) of the support surface, product damage, or product malfunction.