Herunterladen Inhalt Inhalt Diese Seite drucken

Connecting The Connecting Cable (Protective Conductor) - Bosch 1 687 010 393 Originalbetriebsanleitung

Erweiterungssatz für bosch piezo injektoren
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 3
3. Tilt the protective cover forward (see fig. 5).
Fig. 5:
EPS 200 with protective cover tipped forward
4. Remove connecting cable (fig. 6, item 1) from the
protective cover.
5. Remove bolts (4x, fig. 6, item 3).
6. Remove cable bushing (fig. 6, item 4) from the cover
(fig. 6, item 2). To do so, press the cable bushing
into the device.
i
The cover (fig. 6, item 2) is connected on the inside
using a connecting cable (protective conductor). Be-
fore removing the cover (fig. 6, item 2), the connect-
ing cable (protective conductor) must be removed.
7. Remove cover (fig. 6, item 2) upward.
Fig. 6:
Preparing cover for disassembly
Robert Bosch GmbH
8. Remove screw plug (fig. 7, item 1). Retain the hexa-
gon nut (fig. 7, item 4).
9. Push connecting cable 1 684 463 931 (fig. 7, item 2)
through the opening in the cover (fig. 7, item 3).
10. Attach connecting cable 1 684 463 931 (fig. 7,
item 2) with the hexagon nut (fig. 7, item 4).
Fig. 7:
3.4.4
Connect the connecting cable (fig. 6, item 1) to the
protective conductor terminal (fig. 8, item 2).
1
3
2
4
Fig. 8:
| 1 687 010 393 | 19
1
4
Fitting connecting cable 1 684 463 931
Connecting the connecting cable (protective
conductor)
1
2

Connecting the connecting cable (protective conductor)

1 689 989 187
en
2
3
45885-05_Pal
|
2016-12-20

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis