Safety
induSENSOR MSC 7210
Downloaded from
www.Manualslib.com
1.5
Proper Environment
- Protection class:
Displacement sensor type SA, CA:
Controller:
- Operating temperature:
Displacement sensor type SA:
Displacement sensor type CA:
Controller:
- Storage temperature:
Displacement sensor type SA:
Displacement sensor type CA:
Controller:
- Humidity:
- Ambient pressure:
- Shock:
- Vibration:
- EMC:
manuals search engine
IP 67
IP 65
-15 °C bis +80 °C (+5 to + 176 °F)
-40 °C bis +160 °C (-40 to + 320 °F)
0 °C bis +70 °C (+32 to +158 °F)
-40 °C bis +80 °C (-40 to +176 °F)
-40 °C bis +160 °C (-40 to +320 °F)
-40 °C bis +85 °C (-40 to +185 °F)
5 - 95 % (non-condensing)
atmospheric pressure
IEC 68-2-27, IEC 68-2-29
IEC 68-2-6
According to EN 61 326-1: 2006-10 and
EN 61 326-2-3: 2007-05
Page 34