Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data - Baumer DSRK Betriebsanleitung

Messlanze
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

13. Maintenance and repair
Maintenance
Regular maintenance is not required.
14. Disposal
Do not dispose of in household
f
waste.
Separate materials and dispose
f
of in compliance with nationally
applicable regulations.
15. Accessories
For accessories see www.baumer.com.

16. Technical data

Environmental conditions
Operating temperature
range
Storage temperature range
Relative humidity
Protection class
Power supply
Voltage supply range
Current consumption
www.baumer.com
-5 ... +85 °C
-40 ... +85 °C
< 98%
IP54
18 ... 33 V DC
< 50 mA (DSRK U)
< 50 mA (DSRK I)
Operating Instructions
Force and strain sensors
Strain Probe DSRK
Simple strain measurement in deep holes
Repair
Do not repair the strain probe yourself.
Send damaged strain probe to Baumer.
f
Electrical data
Measurement range
Reset input
Reset active
Reset inactive
Reset pulse
Connection
Connector
0 ... 1000 µε
15 ... 45 V DC
> ±15 V DC
< ±5 V DC
> 1 ms
Binder type, series
680/SGR 70, 7-pin
9 / 28