Herunterladen Inhalt Inhalt Diese Seite drucken

Eu Declaration Of Conformity - Cellfast Ergo 55-410 Bedienungsanleitung

Automatische schlauchbox
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 9
WARNING! Failure to comply with the safety precautions may
cause damage of the product or be hazardous to its user and/
or people nearby.
ASSEMBLY INSTRUCTIONS: Choose an installation location for
the wall bracket which will prevent flooding indoor rooms if the
product leaks water. The installation location should be within
the reach of the connection hose (5) connected to the product
and the water tap. The product does not include any wall plugs.
Select the wall plugs which are suitable to the wall material
and the wall bracket bolt hole size.
Wall bracket installation (Fig. C)
1. Place the wall bracket (8) against the wall at the selected
installation location and mark the bolt hole pattern on the wall.
2. Secure the wall bracket (8) to the wall with 4 screws and wall
plugs compatible with the bolt hole size and the wall material
at the marked locations (it is recommended to use washers
between the bolt heads and the wall bracket).
Hang the automatic hose reel (11) on the wall bracket (8) se-
cured to the wall (Fig. E). Do this by releasing the lock tabs into
the position shown in (Fig. D). Engage the lock tabs with the
wall bracket and secure with the wall bracket pin (9). If the wall
bracket pin is difficult to insert, press it inward while twisting it
a little in either direction.
OPERATION (Fig. F): Connect the connection hose (5) to the
water tap with the parts (6-7) or another spout connector
compatible with your water tap. Open the water tap valve.
UNWINDING THE HOSE: Unwind the hose from the reel to the
required length. The reel winding lock is engaged every 50 cm
of hose length and a click is heard every time it is engaged.
WINDING THE HOSE: Approach the automatic hose reel with
the free garden hose end and release the reel winding lock by
pulling a small length of the hose out. The hose starts wind-
ing up on its own at a safe and steady speed controlled by
the integrated winding brake. The reel winding lock gear will
click when unwinding and winding the hose. Before winding
the hose back into the automatic hose reel, undo all knots and
kinks along the unwound length of the hose.
OPERATING CONDITIONS: The product can be operated be-
tween 10°C and 60°C of ambient temperature and supplied
with 6 bars of water pressure maximum. It is best to choose an
installation location away from direct sunlight for as long as
possible to prevent unnecessary overheating of the product.
PRODUCT ADJUSTMENT (Fig. B): You can reposition the hose
stop collar (4) if needed. Caution! Hold the hose (3) when the
hose stop collar (4); otherwise, the hose might be wound up
completely into the reel housing. If this happens, contact the
nearest Cellfast authorized service. 1. Use a screwsdriver to
release 2 bolts (4.1) on the hose stop collar (4). 2. Grasp and
hold the hose firmly while repositioning the hose stop collar
(4). Retighten the 2 bolts (4.1) with the hose stop collar in the
new position.
MAINTENANCE: the product is maintenance-free.
TIP: Mind the hose winding action. Before winding the hose
back into the reel, clean it of heavy soil and dirt, otherwise the
automatic hose reel might not wind the hose back properly.
AT THE END OF WORK WITH THE PRODUCT: Before winding
the hose, close the water tap valve and open the sprinkler at-
tached to the hose end to release the water from the hose.
TROUBLESHOOTING: If the hose is difficult to wind into the au-
tomatic hose reel (because the hose is knotted or kinked, etc.),
close the water tap valve, unwind the full length of the hose,
remove all its knots and kinks, and try to wind the hose back
in. If this does not help, contact the nearest Cellfast author-
ized service. No spare parts are commercially available for this
product (except for quick connectors, the universal connector
and the sprinkler). If the product requires warranty or post-war-
ranty repairs, contact the nearest Cellfast authorized service.
REPLACING THE HOSE: For safety reasons, have the garden-
ing hose replaced by Cellfast's authorized service only.
TRANSPORT: Handling: Graps the carrying handles (10) and
remove the wall bracket pin (9) up while slightly twisting it left
an right.
STORAGE / WINTERIZING: Keep the automatic hose reel pro-
tected against freezing in winter.
WARNING! To avoid accidents and injury, mind the product
weight (8.3 kg / 18.5 lbs) when choosing the storage location.
NOISE EMISSION: the winding action of the product generates
an average noise level of 85 dB.

EU DECLARATION OF CONFORMITY

Cellfast hereby declares that the product specified below
has its concept, design and commercially available produc-
tion version in conformity with the prevailing requirements
of the EU Directive concerning health and safety. All alter-
ations or modifications of this product not authorized by
Cellfast will void this declaration.
Automatic hose reel ERGO™
Art. no. 55-410
Prevailing EU Durectives: 2006/42/EC
Applied harmonized standards: EN ISO 12100
The undersigned who act by authorization and commission of
Cellfast Sp. z o.o. management.
Authorized personnel: Bogusław Frączek
Stalowa Wola, 2020.03.10
Cellfast Sp. z o.o.
ul. W. Grabskiego 31
PL 37-450 Stalowa Wola
info@cellfast.com.pl
www.cellfast.com.pl
PL
BG
CZ
DA
DE
EE
EN
ES
FI
FR
GR
HR
HU
IT
LT
LV
NL
NO
PT
RO
RU
SK
SL
SQ
SR
SV
TR
UA
13

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis