MOUNTING THE WATER SOFTENER ON THE
PREMOUNTED BYPASS VALVE
The connection flange of the water softener is covered by a white protector cap. This protector cap is se-
cured by four cylinder screws M6×100.
Do not grasp into the connection flange of the device after removing the white
protector cap (crush hazard)!
/
Loosen all four cylinder screws M6×100, but don't remove them (bayonet fixture).
/
Remove the white protector cap.
The section of the profiled flange gasket must point towards the built-in rotary flange (see fig. 3). Failure
to observe this can lead to leaks and water escaping. This can in turn cause water damage to the house and
its installations.
/
Lift up the water softener and swivel it through approx. 30° in an anti-clockwise direction.
/
Position the water softener on the flange of the bypass valve marked with the cast in letter "G" (unit
flange) so that the screw heads pass through the bayonet fixing drill holes (see fig. 5 I).
/
Swivel the softener through approx. 30° back in a clockwise direction (see fig. 5 II).
/
Tightly fasten the four cylinder screws M6×100.
Select the torque (approx. 4 Nm) so that the gasket closes and the water softener
is not damaged or strained!
After assembling the water softener unscrew the wall support so far that it rests against the water soften-
er casing and the water softener hangs vertically to the wall.