Herunterladen Inhalt Inhalt Diese Seite drucken

Mounting The Bypass Valve (Accessories) - Conel CLEAR Serie Montage- Und Betriebsanleitung

Vorschau ausblenden Andere Handbücher für CLEAR Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

5.8

MOUNTING THE BYPASS VALVE (ACCESSORIES)

When assembling a bypass valve between the built-in rotary flange and the water softener, a continuous
supply of untreated drinking water is also possible during any maintenance work on the water softener.
/
Firstly flush the pipe with the newly installed built-in rotary flange. The built-in rotary flange is still
closed by the black assembly cover.
/
Then shut off the water again (at the main water tap or shut-off valve) and remove the assembly cover
of the built-in rotary flange.
/
Connect the bypass valve on the flange side with the cast in letter "R" (pipe flange) to the built-in rotary
flange by engaging the bayonet fitting (see fig. 6).
Unit flange
("G")
/
Tightly fasten the four cylinder screws M6×25.
Select the torque (approx. 4 Nm) so that the gasket closes!
The handwheel of the bypass valve can be positioned anywhere to the top or to the side. Depending on
conditions on site, installation should be carried out ensuring sufficient access to the handwheel.
Handwheel
Pipe flange
("R")
Fig. 6: Bypass valve
Built-in rotary flange
63

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Clear soft twin

Inhaltsverzeichnis