2. Set the temperature controller to operation with cold
or hot water.
3. Push the safety latch backwards.
The high-pressure gun is unlocked.
4. Open the high-pressure gun.
5. Start the motor with the high-pressure gun open ac-
cording to the original motor instructions.
If cleaning does not start immediately, secure the high-
pressure gun (see chapter Interrupting operation).
Cleaning
1. Adjust the pressure and temperature according to
the surface to be cleaned.
Cold water operation
1. Set the temperature controller to the "Burner off" po-
sition.
Operation with hot water
DANGER
Hot water
Risk of scalding
Avoid contact with hot water.
1. Set the temperature controller to the desired work-
ing temperature.
The burner is switched on.
Operation with detergent
Note
A cup foam lance (optional)is needed for operating with
detergent.
WARNING
Incorrect handling of detergents
Health risk
Adhere to the safety instructions stated on the detergent
packaging.
ATTENTION
Unsuitable detergents
Damage to the device and the objects to be cleaned
Use only detergents approved by KÄRCHER.
Observe the dosing recommendations and notes pro-
vided with the detergent.
Use detergents sparingly to help conserve the environ-
ment.
ATTENTION
Water temperatures too high
Damage to the cup foam lance
The cup foam lances are only suitable for water temper-
atures up to 60 °C. For operation with detergent, do not
select water temperatures above 60 °C.
KÄRCHER detergents ensure fault-free operation. Ask
us for a consultation, request our catalogue or our de-
tergent information sheets.
Cup foam lance 4.112-054.0
Illustration G
Container
1
Foam nozzle
2
EASY!Force high-pressure gun
3
Suction hose
4
Gate
5
Detergent mixing: 3=high, 2=medium, 1=low
1. Unscrew the container.
2. Plug the desired gate into the suction hose.
3. Fill the detergent into the container.
4. Screw the container on to the foam lance.
20
5. Remove the spray lance from the high-pressure
gun.
6. Attach the foam lance to the high-pressure gun and
hand-tighten it.
7. Start up the high-pressure cleaner.
Cup foam lance 2.112-018.0
Illustration H
Container
1
Spray form twist grip
2
Detergent dosing rotary knob
3
EASY!Force high-pressure gun
4
1. Unscrew the container.
2. Fill the detergent into the container.
3. Screw the container on to the foam lance.
4. Remove the spray lance from the high-pressure
gun.
5. Attach the foam lance to the high-pressure gun and
hand-tighten it.
6. Start up the high-pressure cleaner.
7. Adjust the detergent dosing unit using the detergent
dosing rotary knob.
8. Adjust the jet width using the spray form twist grip.
Recommended cleaning method
1. Spray the detergent sparingly on the dry surface and
let it work for a while (do not let it dry).
2. Rinse off the loosened dirt with the high-pressure
jet.
Rinsing the cup foam lance
The foam lance must be rinsed after use to prevent the
development of detergent deposits.
1. Unscrew the container.
2. Pour the remaining detergent back into the original
packaging.
3. Fill the container with clear water.
4. Screw the container onto the foam nozzle.
5. Operate the foam nozzle for approx. 1 minute to
flush the detergent residue.
6. Empty the container.

Interrupting operation

1. Close the high-pressure gun.
2. Push the safety latch forwards.
The high-pressure gun is secured.
Note
If the high-pressure gun is closed, the motor continues
to run at idle speed. The water then circulates within the
pump and heats up. When the cylinder head at the
pump has reached the maximum permissible tempera-
ture (80 °C), the thermostat valve on the pump opens
and lets out the hot water into the open. Cooling can be
accelerated when operating with pressurized water
from the water pipe network:
3. Open the high-pressure gun for about 2-3 minutes.
The water flowing through it cools the cylinder head.
DANGER
Hot water
Risk of scalding
After operation with hot water, operate the device for at
least 2 minutes with cold water with the high-pressure
gun open for cooling down.
English