Herunterladen Inhalt Inhalt Diese Seite drucken

TECO 100 Variant Betriebs- Und Wartungsanleitung Seite 52

Vorschau ausblenden Andere Handbücher für 100 Variant:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 81
machine not powered.
- Restore the electric connections.
Defective inverter.
- Replace the inverter (skilled staff needed in this case).
motor shorted.
Replace the motor (skilled staff needed in this case).
Belt broken.
• Replace belt.
Rotation control pedal fails to return to central position
Control spring broken.
• Replace the control spring.
Bead breaking unit not working
No vertical movement.
• Check for folded hoses.
• Check ascent and descent valve operation.
Bead breaking unit is underpowered, does not break the bead and is
leaking air
Carry out the checks in the previous point: "Bead breaking unit not working".
Cylinder gaskets worn.
• Replace gaskets.
• Replace bead breaker cylinder.
Bead breaker cylinder leaks air around the rod
Air gaskets worn.
• Replace gaskets.
• Replace bead breaker cylinder.
Gear unit noisy. The table top makes 1/3 of a spin and then stops
Gear unit seizing.
• Replace gear unit.
Table top fails to clamp rims
Handle engagement unit faulty.
• Check it is synchronised properly.
• Replace the plate of the turntable.
• Check there are no burrs.
• Replace the locking handle.
Table top mounts or demounts wheels with difficulty
Insufficient belt tension.
• Adjust tension or replace belt.
Vertical head does not raise or does it too far from rim
Clamping plate not adjusted.
• Adjust plate.
• Restore setting.
Vertical head does not raise or does it too far from rim
Clamping plate not adjusted.
• Adjust plate.
• Restore setting.
Vertical and horizontal limit stops do not operate
No air passing through clamping handle / valve.
• Check hose circuit.
• Replace handle / valve.
User manual TECO 100 Variant
52

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis