Safety Instructions - HBM T40FM Montageanleitung

Drehmoment-messflansch
Vorschau ausblenden Andere Handbücher für T40FM:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

T40FM

Safety instructions

Proper use
The T40FM torque flange is used exclusively for torque, angle of rotation and
power measurement tasks within the load limits stipulated in the specifica­
tions. Any other use is not the designated use.
Stator operation is only permitted when the rotor is installed.
The torque flange may only be installed by qualified personnel in compliance
with the specifications and with the safety requirements and regulations of
these mounting instructions. It is also essential to observe the applicable legal
and safety regulations for the application concerned. The same applies to the
use of accessories.
The torque flange is not intended for use as a safety component. Please also
refer to the section: "Additional safety precautions". Proper and safe operation
requires proper transportation, correct storage, siting and mounting, and care­
ful operation.
Loading capacity limits
The data in the technical data sheets must be complied with when using the
torque flange. In particular, the respective maximum loads specified must
never be exceeded. The following limits set out in the specifications must not
be exceeded, e.g.:
 Limit torque
 Longitudinal limit force, lateral limit force or bending limit moment
 Torque vibration bandwidth
 Breaking torque
 Temperature limits
 Limits of electrical loading capacity
Use as a machine element
The torque flange can be used as a machine element. When used in this
manner, it must be noted that, to favor greater sensitivity, the transducer is not
designed with the safety factors usual in mechanical engineering. Please refer
here to the section "Loading capacity limits" and to the specifications.
Accident prevention
According to the prevailing accident prevention regulations, once the trans­
ducers have been mounted, a covering agent or cladding has to be fitted as
follows:
 The covering agent or cladding must not be free to rotate.
A3276-2.1 en/de