Herunterladen Inhalt Inhalt Diese Seite drucken

HBM T40FM Montageanleitung Seite 47

Drehmoment-messflansch
Vorschau ausblenden Andere Handbücher für T40FM:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

T40FM
Group delay
Option SU2
Option DU2
Option HU2
Temperature effect per 10 K in the
nominal (rated) temperature range
on the output signal, related to the actual
value of the signal spread
on the zero signal, related to the nominal
(rated) sensitivity
Long‐term drift over 48h at reference
temperature, related to nominal (rated)
sensitivity
Torque measuring system, voltage output
Nominal (rated) sensitivity (spread
between torque = zero and nominal (rated)
torque)
Sensitivity tolerance (deviation of the
actual output quantity at M
nominal (rated) sensitivity)
Linearity error including hysteresis,
related to the nominal (rated) sensitivity
optional
Relative standard deviation of
repeatability (variability),
per DIN 1319, related to the variation of
the output signal
Output signal at torque zero
Nominal output signal
at positive nominal (rated) torque
at negative nominal (rated) torque
Maximum control range
invalid measured value
Load resistance
3)
Residual ripple
Temperature effect per 10 K in the
nominal (rated) temperature range
on the output signal, related to the actual
value of the signal spread
on the zero signal, related to the nominal
(rated) sensitivity
Long‐term drift over 48h at reference
temperature, related to nominal (rated)
sensitivity
2)
Output signal range in which there is a repeatable correlation between torque and output signal.
3)
Signal frequency range 0.1 to 10kHz.
A3276-2.1 en/de
s
s
s
%
%
%
V
from the
%
nom
%
%
%
V
kHz
kHz
2)
V
V
k
mV
%
%
%
<400
<220
<150
<"0.1
<"0.05
0.03
10
"0.2
<"0.1
<"0.05
<"0.05
0
10
-10
"12
13 ... 15
>10
< 40 (peak‐to‐peak)
0.2
<"0.15
<"0.03
47