Error Messages; Coded Messages - Georg Fischer Piping Systems MSA Plus 400 Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Operating instructions MSA Plus 400
6

Error Messages

6.1

Coded Messages

E Display
2
MAINS VOLTAGETOO HIGH
5
AMBIENT TEMP. TOO LOW
6
AMBIENT TEMP. TOO HIGH
7
INTERNAL TEMP. TOO LOW
8
INTERNAL TEMP. TOO HIGH
9
FITTING RESISTANCE TOO
LOW
10
FITTING RESISTANCE TOO
HIGH
11
FUSION VOLTAGE TOO LOW
12
FUSION VOLTAGE TOO HIGH
13
FUSION CIRCUIT
INTERRUPTED
14
FUSION CURRENT TOO HIGH If this occurs frequently, either the
15
POWER SUPPLY TEMP. TOO
LOW
16
POWER SUPPLY TEMP. TOO
HIGH
21
OUTAGE DURING LAST
FUSION
22
FUSION INTERRUPTED WITH
STOP
28
UNIT RANGE EXCEEDED
63
MEMORY CARD REMOVED
71
SYS.-ER. MEASUR. AMBIENT
TEMP.
72
SHUTDOWN DUE TO MAGN.
INFLUENCE
74
FUSION POWER TOO LOW
75
FUSION POWER TOO HIGH
78
POWERSUPPLY ERROR
(10.07)
Comments
Check functioning of generator
Allow MSA Plus 400 to warm up in a
heated room
Allow MSA Plus 400 to cool off
Check fitting
Check fitting
Check generator output/extension
cord
If this occurs frequently, send MSA
Plus 400 in for servicing
Check the power
connection/extension cord
fitting is defect or the MSA Plus 400
needs servicing
Allow MSA Plus 400 to warm up in a
heated room
Allow MSA Plus 400 to cool off
Check the last fusion operation
Check the last fusion operation
Use a fitting which can be joined with
the MSA Plus 400
Switch off MSA Plus 400, insert the
Protocol record card
Send MSA Plus 400 in for servicing
Move MSA Plus 400 away from the
generator
Check the generator output/extension
cord
If this occurs frequently, send the
MSA Plus 400 in for servicing
Send MSA Plus 400 in for servicing
MSA Plus 400_e.doc
6 Error Messages
29