Manual entry of the length (may only be entered by keyboard):
LENGTH:
ELEMENT 1
002.10 m
UP
DWN
The position of the cursor is indicated by a blinking question mark.
When entering data by keypad, the sequential numeral must according to the
standard ISO 12176-4.
4.9

Manual input of fusion programme Z45

The function allows the operator to enter the fusion programme as an
interleave 2/5 numerical code using the buttons on the fusion machine.
The user can read in the fusion programme as per usual or alternatively, he
can enter the digits under the barcode using the input buttons.
FUSION DATA?
7.15
MNU
MNU
FUSION DATA?
3736?30321999140
57050303
UP
DWN
If the numbers are added correctly with the UP, DWN, LFT, RGT buttons, the
next display appears. If the numbers are put in incorrectly / are not compatible
with the standard, the information 'FUSION PROGRAMME INCORRECT' will
appear. After a few seconds, the standard display will appear.
Under Configuration in the menu, the operator has the possibility to activate
the Z45 function with the Z45 configuration barcode (Z45,1) or to deactivate it
with Z45,0. If the Z45 function is deactivated (Z45,0), the button EDT does not
appear on the display and the fusion process is carried out as normal.
(10.07)
Operating instructions MSA Plus 400