2 Operation with Standard Configuration
6
2.4

Start Fusion Process

The MSA Plus 400 is now ready for fusion.
Press START to initiate fusion.
GF I *
7.15
MNU
MNU
During the first seconds of the fusion, the quality of the input voltage is
checked. If the input voltage is insufficient, the fusion is interrupted after a few
seconds. In this case, a default message is shown (see chapter «default
messages»).
CHECKING
POWER SOURCE
31s
2.5

Terminate Fusion

The fusion process can be terminated at any time by pressing STOP. In this
case, an error message will appear. (See chapter «Error Messages»)
2.6

Finish Fusion

The fusion operation data is stored in memory.
GF I *
OK
38s
UP
DWN
COOLING TIME IN
MINUTES:
UP
DWN
If no cooling time is required by the fusion program of the fitting, only the
protocol will be displayed.
When the cooling time is over, the external fitting clamp can be removed.