Herunterladen Inhalt Inhalt Diese Seite drucken

Data Sheet Ultrasonic Level Sensor Luc 4 - Pepperl+Fuchs LUC4T-G5S-IU-V15 Handbuch

Serie luc4
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

- active fixed target supression
- temperature compensation
- 12 bit DA-converter
- compact design
- plug connection
- simple calibration
- function check
- fail-safe-function when echo
missing
- output signal 4 ... 20 mA / 0 ... 10V
Membrane PTFE
LUC4T-G5S-IU-V15
LUC4T-G5P-IU-V15
LUC4T-N5S-IU-V15
LUC4T-N5P-IU-V15
Function principle
The ultrasonic sensor transmits an
ultrasonic pulse which is reflected
at the mediums surface. After the
pulse returns to the sensor, the
level is calculated by a micropro-
cessor.
Source of interferences like weld
seams, fixed target, etc are reliably
supressed.
Changes of the ultrasonic speed
caused by changing temperatures
are compensated.
Types
LUC4 T-o5o-IU-V15
thread material
thread
membrane surface
Subject to reasonable modifications due to technical advances.
18
Pepperl+Fuchs Group · Tel.: Germany (6 21) 7 76-22 22 · USA (3 30) 4 25 35 55 · Singapore 779 90 91 · Internet http://www.pepperl-fuchs.com
Dimensions
10°
Sound cone
55
G1½A
callibration- and
configuration plug
LED
fault (red)
Plug positions:
A1:
calibration "empty"
E2/E3: teach-in of the fixed target
A2:
calibration "full"
T:
operation
Accessories:
i.e.: external temperature sensor LUC4-Z30-N2V
Plug connection V15 resp. V1
1
4
2
5
3
Ultrasonic Level Sensor
V15-plug
ø44
LED
operation (green)
M12x1
calble length: 300 mm
1
4
4 ... 20 mA
2
0 ... 10 V
3
5
Copyright Pepperl+Fuchs, Printed in Germany
LUC 4
+U
B
- U
B
n.c.

Werbung

Kapitel

Inhaltsverzeichnis
loading