Technical data
Measuring ranges
Accuracy
Resolution
Supply
Supply voltage
Ripple wave
Power consumption P
L
Output
Current
Voltage
RS-232-interface
Indicators
Operation
Fault
Current output
Voltage output
Environmental conditions
Temperature
Storage
Process conditions
Temperature
Pressure
Electrical connection
Process connection
LUC
-G5S
oo
LUC
-G5P
oo
LUC
-N5S
oo
LUC
-N5P
oo
Membrane surface
LUC 4 T
Calibration and configuration plug
A1
E2/E3
A2
T
Housing material
Protection class acc. to DIN 40 050
Mounting
Accessories
LUC4-Z30-G2V
LUC4-Z30-N2V
V1-G-2M-PVC
V1-W-2M-PVC
A measuring system consists out of:
- an ultrasonic level sensor LUC4T-
but can also be connected directly to a PLC
Subject to reasonable modifications due to technical advances.
Pepperl+Fuchs Group · Tel.: Germany (6 21) 7 76-22 22 · USA (3 30) 4 25 35 55 · Singapore 7 79 90 91 · Internet http://www.pepperl-fuchs.com
0.3 m ... 4 m, with liquids
0.5 % from the full scale
2 mm
DC 10 ... 30 V
± 10 % ss, Û
=33 V
B
≤ 1200 mW
≤ 500 Ω
4 ... 20 mA, R
L
≥ 1 kΩ
0 ... 10 V, R
L
exisiting
LED green
LED red, 2 Hz flashing
≥ 21 mA
≥ 10.5 V
-25 °C ... +70 °C (248 K ... 343 K)
-40 °C ... +85 °C (233 K ... 358 K)
-25 °C ... +70 °C (248 K ... 343 K)
atmospheric
V15-plug (M12x1) ot V1 (M12x1)
Thread G1½A, stainless steel 316 Ti / 320 S 18
Thread G1½A, Polypropylene
Thread 1½" NPT, stainless steel 316 Ti / 320 S 18
Thread 1½" NPT, Polypropylene
PTFE
Compensation "empty"
Teach-in / fixed target suppression
Compensation "full"
Operation
PBT
IP 55
Ultrasonic pulses must be mounted perpendicular to the medium level
External temperature probe, G½A
External temperature probe, ½"NPT
Cable connecting box, straight, 2 m PVC cable
Cable connecting box, 90
5
-IU-V15 and a display (e. g. DA5) or a 3-wire-transmitter repeater unit,
o
o
Ultrasonic Level Sensor
angled, 2 m PVC cable
o
Copyright Pepperl+Fuchs, Printed in Germany
LUC 4
19