• One of the two included metal pipes has a small slot at the end. Plug the Y-holder right into this end, so that the
plastic tab at the Y-holder rests precisely in the slot of the metal pipe.
Then the Y-holder is fastened to the metal pipe with a long screw
(A) and a nut (D).
• One of the two L-holders is screwed to the metal pipe so that the
square plug-on socket (See arrow) points up towards the wind sensors
(distance to the top end of the metal pipe about 5-10 cm).
• Then the rain sensor must be put on the plug-on socket and screwed
on with the small screw (C).
The figure above shows that the rain sensor is plugged onto the L-holder longitudinally. It can also be put
on the square plug-on socket tuned by 90° so that water can run off better and will not run onto the L-
holder.
If desired, the rain sensor can be installed in a place father away as well instead of at the mast, due to its
long connection cable.