Herunterladen Inhalt Inhalt Diese Seite drucken

Switching Off And Storage - Comet KA Classic Serie Bedienungs- Und Wartungsanleitung

Elektrische kaltwasser-hochdruckreiniger
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 42
CAUTION
• Make sure that the tank (5) is replaced in the correct position, especially regarding the detergent
suction pipe (37).
All high-pressure cleaners can also take up detergents from an external tank. This is also possible if the
tank (5) contains detergent as the suction from the internal tank is automatically interrupted (also refer
to following section).
• If using suction from an external tank (also see Fig. 3), unscrew the cap (35) and insert the coupling (36)
for the detergent suction pipe for an external tank (31) into the coupling (38). The external tank should
already contain the chosen detergent. Again, follow the recommendations regarding the doses indicated
on the label on the container of detergent.
• Operate the nozzle head (23) or (24) as illustrated in Fig 3a and then operate the lever (33) on the cleaner
gun and start the releasing the detergent.
• Turn the detergent adjustment control knob (4) to achieve the required amount of product.
• Operate the nozzle head (23) or (24) as illustrated in Fig 3b to restore high-pressure operation.
CAUTION
• After use of the high pressure cleaner with external tank, take care to replace the cap (35) correctly in
the coupling (38) to safeguard the correct suction of detergent from the high-pressure cleaner's tank (5).
5.4 I
nterruptIng use
5.4.1 Interrupting use when operating pressure is between 0÷20 bar/0÷290 psi
Release the lever (33) on the cleaner gun and the high-pressure cleaner will change from operational
mode to bypass mode and remains in bypass mode until the lever (33) is pressed again.
CAUTION
• Do not leave the high-pressure cleaner in bypass mode for more than three minutes (with cleaner
gun closed).
5.4.2 Interrupting use when operating pressure is above 20 bar/290 psi (Total Stop)
Release the lever (33) on the cleaner gun and the high-pressure cleaner will automatically stop.
The high-pressure cleaner starts operating normally again when the lever on the cleaner gun is pressed
again.
WARNING
• It is important to remember that the high pressure cleaner is still operational when it is in Total Stop
mode. Therefore, always put the main switch (1) in position "0", remove the plug from the power outlet,
press the lever (33) on the cleaner gun to eliminate any remaining pressure and lock the safety protection
device (32) (Fig. 2 – position s), before leaving it unattended, even for a short time.
Note 5: during use with operating pressure in excess of 20 bar/290 psi (i.e. when the Total Stop device
is operational) if switch (1) is put into position "0" for any reason (and lever (33) on the cleaner gun is
not being operated to eliminate any remaining pressure) the next time the switch (1) is put into position
"1", the high pressure cleaner will not begin to start up as it is already ready for normal operation. Press
lever (33) on the cleaner gun to start operating the high-pressure cleaner.

6 Switching Off And Storage

After cleaning, switch the high-pressure cleaner off and prepare it for storage.
6.1 s
wItchIng off
• Close the tap for the water supply securely.
• Empty the water out of the high-pressure cleaner by pressing the lever (33) on the cleaner gun for a few
minutes.
• Put the main switch (1) in position "0"
• Remove the plug from the power outlet.
• Press the lever (33) on the cleaner gun to eliminate any remaining pressure in the high-pressure pipe (30).
• Wait for the high pressure cleaner to cool down.
26

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ka excel serieKa classic 2800 mKa classic 3000 mKa classic 3200 mKa classic 4000 tKa classic 5000 t ... Alle anzeigen

Inhaltsverzeichnis