The recommended detergents, are over 90% biodegradable.
For information on how to use the detergents, refer to the instructions in the table below and on
the label on the container of detergent.
• Fill the bottle (23) with the desired detergent
• Regulate the detergent suction capacity in the following way:
- disconnect the rod (22) from the lance (21);
- the L tooth on the rod (22) must match with one of the numbers on the inside of the lance (21)
(1: minimum suction, 6: maximum suction);
- re-connect the rod (22) in the lance.
• Insert the bottle (23) in the foam lance (21).
• Connect the lance (21) to the gun (16), turn on the machine and work the lever (28) (suction and
mixing happen automatically with the passing water).
5.4 I
NTERRUPTING
Release the lever (28) on the cleaner gun and the water cleaner will automatically stop.
The water cleaner starts operating normally again when the lever on the cleaner gun is pressed
again.
fi«
CAUTION
• It is important to remember that the high pressure cleaner is still operational when it is in Total
Stop mode. Therefore, always put the main switch (2) in position "0", remove the plug from
the power outlet, press the lever (28) on the cleaner gun to eliminate any remaining pressure
and lock the safety protection device (29) (Fig. 2 - position F), before leaving it unattended,
even for a short time.
6 S
O
WITCHING
After cleaning, switch the water cleaner off and prepare it for storage.
6.1 S
O
WITCHING
FF
• Close the tap for the water supply securely.
• Empty the water out of the water cleaner by pressing the lever (28) on the cleaner gun for a few
seconds.
• Put the main switch (2) in position "0"
• Remove the plug from the power outlet.
• Press the lever (28) on the cleaner gun to eliminate any remaining pressure in the high-pressure
pipe (7) or (24).
• Rewind the power supply cable (14) with care and hook it to its support (11).
• Wait for the high pressure cleaner to cool down.
fi«
CAUTION
• When the water cleaner is left to cool down, take care that:
- the water cleaner is not left unattended in the presence of unsupervised children, elderly
or disabled people.
- the water cleaner is in a stable position and not at risk of falling over.
- the water cleaner is not in contact with inflammable materials, or in their immediate
vicinity.
U
(
)
SE
TOTAL STOP
S
FF AND
TORAGE