5. Turn off
5.1. General
Put the operating switch on OFF when you fi nish the works.
5.2. Chemicals tank
Pull the sucking hose out of the chemicals tank and hang it in a bucket with clean water.
Seal the chemicals tank with a cap.
Rinse everything, to remove chemicals out off the hoses, lance and pistol.
5.3. Lance and gun
Uncouple the lance and put it away.
Close the water supply.
Roll up the high and low pressure hoses.
5.4. Water outlet
See chapter 1 - safety and 2.1.2.
5.5. Put away machine
Clean when necessary the water fi lter.
See that the machine is parked frost-proof.
Clean , if necessary, the water fi lter.
5.6. Transport
Pay attention at transport to the following:
Keeps the machine as much as possible horizontal during transport, one prevents that there leaks oil from the
pump.
Load the machine using a lift truck, hydraulic loading platform or a hoist.
Lash the machines (if necessary) sound fi xed on the loading platform.
5.7. Transportation at frost
Replace the water sucking hose by a short piece hose and hang it with his end in the anti-frost, so the machine
can suck the anti-frost.
Take the lance from the gun and operate the machine.
Spray until there comes anti-frost out of the gun.
The machine is now fi lled with anti-frost, stop the machine.
Tip: Because the catch of the outgoing anti-frost water, this can be re-used afterwards.
DiBO n.v. 40