Herunterladen Inhalt Inhalt Diese Seite drucken

Before Bring In Use; Accomplish Water Supply And Water Outlet; Accomplish Water Supply; Carry Away Water - Dibo ECN Serie Gebrauchsanweisung

Vorschau ausblenden Andere Handbücher für ECN Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Chemical cleansing agents: (if necessary)
Read always fi rstly the regulations on the packing of the product.
Never clean with infl ammable products.
See for separate care/cleaning of evacuation water.
See for the necessary personal protective equipment (glove, clothing, optical device...).
Put the chemicals tank directly beside the machine. Remove the fi ller cap and hang the supply-hose in the tank.
Traffi c:
Protect piping and cables which run over a roadway with dock boards.
Personal security measures:
The machine not move during the use.
Avoid a bad posture.
Consult at skin penetration immediately a doctor and communicate certainly the type of used product.

2. Before bring in use

For each start up all substantial parts of the high pressure cleaner must be checked by taking them in considera-
tion like for example: is the lance joint still stuck fi rmly, check high pressure hoses and electric wiring on damages.
Check, before plugging the plug in the socket, if the electric indications on the name blade are suitable with the
values of the main supply (for example: electric tension,...).
Operating the machine. Rinse the hoses, gun and lance minimum 1 minute with clean water.
(Aim the gun in the free space). Check if of the object to clean can come dangerous goods like e.g. asbestos and oil
loose and can pollute the environment.
Persuade yourself of the safety regulations from previous chapter.
Leaves the main - and operating switch on state OFF.

2.1. Accomplish water supply and water outlet

2.1.1. Accomplish water supply

The water supply pipe can be connected (towards circumstances) on their own water supplies (under pres-
sure) or on a drinking water supply with a water barge. When the machine is connected to the drinking water
supply, the existing regulations about that must be observed ( EN 1717 ).
Water supply under pressure:
Maximum hose length 50m ( 160ft ), minimum hose diameter ( inside ) 12.7mm (1/2").
Check the water pressure using a water meter.

2.1.2. Carry away water

Check that all water outlets have been correctly connected on the sewerage.
Take the necessary measures so that the effl uent is pure enough to drain.

2.1.3. Anti-legionella bacterium measure

If the machine has stood still some time, the water in the machine must be drained above an evacuation.
Stationary water that between 20-55°C warm is can cause the legionella bacterium.
DiBO n.v. 36