For expert winterization of your spa, contact your author-
ized dealer.
In emergency situations, damage can be minimized by taking the
following steps:
- Disconnect the spa from the electric mains.
- Follow the directions for draining the spa.
- Remove the water from the recessed seating areas and bottom.
- Position the massage switch in position A (combo).
B
C
A
- Open the valve of the cascade with the correct knob.
- Remove the side cover panels and locate the pump drain plugs. Re-
move them to allow water to drain from the pumps and the heater.
Use a vacuum or other means to keep the water from flood-
ing the system compartment.
- Re-install the plugs of the pumps and the cabinet panels and cov-
er the spa with the insulating cover.

Restarting your spa in cold weather

If you want to start up your spa after it has sat empty for a time
in freezing temperatures, check whether the water remaining in
certain sections of the piping is still frozen: this situation may
block water flow preventing the spa from operating properly and
possibly damaging the equipment.
We recommend you consult your dealer for guidance before
attempting to restart your spa under these conditions.
CLEARRAY™ Water Purification System
CLEARRAY Water Purification System is exclusive technology
utilizing natural ultraviolet technology to eliminate waterborne
bacteria, viruses, and algae in portable spas. The ultraviolet light
otherwise know as UV-C or germicidal light inactivates the mi-
croorganisms disrupting the DNA so that it cannot reproduce and
is considered lifeless. CLEARRAY is plumbed in-line with your
filtration system. After the water is drawn from the pump, filter,
and heater it is then directed though the CLEARRAY system. Wa-
ter passes through an ultraviolet light energy that treats and
disinfects the water. The water is then pumped back into the s-
pa giving you crystal clear water instantly. The system has a bal-
last that is the power supply for the purification system; it has
two LED indicator lights the green indicating incoming power
flow and the red indicating the system is properly working.
CLEARRAY is standard for all models.
Note: The CLEARRAY System only runs when the jets pump 1
is running.
After a year the lamp bulb must be replaced. If the UV timer has
been programmed correctly a message will appear on the LED
display when the time allotted has expired. In order to clear the
"blb" message a new UV lamp bulb needs to be installed and the
timer must be reset.
Conditions and error messagess
"Summer" mode (models with circulation pump)
I
If the water temperature exceeds the set temperature by 1 °C,
the spas enter "summer" mode. The circulation pump is auto-
matically deactivated.
I
Summer mode is not activated until water temperature reach-
es 35 °C.
To help prevent a "Summer Mode" condition, it may be nec-
essary to reduce the filtering/heating cycle in warm weather.
Overheating
Overheat protection. Heater is deactivated.
Do not get into the spa, the water may be too hot.
- To correct the situation:
I
Remove the spa's cover and allow your spa to cool down.
I
Program the filter settings for "Economy" mode.
I
When the water temperature drops below 44°C, the spa will
resume normal operation.
I
If the temperature does not drop below 44°C, contact a Jacuzzi
Service Centre
Keep in mind that the spa's ability to cool is directly affected by
the ambient temperature: an excessively hot ambient tempera-
ture may prevent the spa from cooling down because its fully in-
sulated construction is designed to retain heat and to minimize
operating costs.
Panel Displays BLB
UV lamp needs to be replaced. The message will flash between
"blb" and the water temperature. The countdown timer for the
UV lamp needs to be reset.
I
Contact an authorized Jacuzzi Service Centre.