- before leaving the high power cleaner unattended, even for only a short time;
- after use;
In addition, wait until the high pressure cleaner has completely cooled down before cleaning
or maintenance.
• During use, do not lock the lever (28) on the cleaner gun in the open position.
• Do not remove the plug from the power outlet by pulling on the power supply cable.
• Do not put any reducers or adaptors between the electric plug and the power outlet.
• Keep the power supply cable, any extension cords, the plugs and the outlets dry. Do not touch
them with wet hands.
• If the supply cord is damaged, it must be replaced by the Manufacturer or by a Skilled
Technician, in order to avoid a hazard.
• Do not cover the high pressure cleaner during operation and do not place it where there is
inadequate ventilation.
• When the high pressure cleaner is used in enclosed spaces, make sure that there is adequate
ventilation.
5.1 P
P
RELIMINARY
• Unroll the high-pressure pipe (7) or (24) completely.
• Attach a supply pipe to the water inlet's quick connection (27) using a normal garden connector
(operation E - Fig. 3).
• Open the tap to the water supply and make sure that there are no drips (operation F - Fig. 3).
• Make sure that the main switch (2) is in the off position (the "0" position) and put the plug into
the electric current outlet (operation G - Fig. 3).
• Push the main switch (2) to position "1".
• Press the cleaner gun's control lever (28) and wait for a continuous jet of water to be issued.
• Turn the main switch (2) to position "0" and connect the lance pipe (17) to the cleaner
gun (16).
5.2 S
O
TANDARD
PERATION
• Restart the high pressure cleaner by turning the main switch (2) to position "1".
Note: during this restart phase, the high pressure cleaner will immediately stop operating after
the initial peak, as the Total Stop device will take effect.
• Use the cleaner gun's lever (28) to start operation of the high pressure cleaner and thus start
cleaning.
• Re-start the water cleaner by setting the main switch (2) to position "1".
5.3 U
D
SE WITH
ETERGENTS
fi«
CAUTION
• The high pressure cleaner was designed to be used with the detergents recommended by the
Manufacturer. Use of other detergents or chemicals can affect the safety of the high pressure
cleaner.
Never suck up liquids, which contain solvents, petrol, diluents, acetone and fuel oil, as these
products are highly inflammable, explosive and toxic when nebulized.
• Carefully read the instructions and warnings on the label of the detergent to be used.
• Store detergents in a safe place out of children's reach.
• Should detergent come into contact with your eyes, wash immediately with water. Contact a
doctor without delay and remember to take the container of detergent with you.
• If detergent is swallowed, do not provoke vomiting. Contact a doctor without delay and
remember to take the container of detergent with you.
30
ROCEDURES
(
HIGH PRESSURE
)