c) Mount the hose (5) between the hose reel and the water cleaner, by tightening the two fast
coupling connectors (operation D - Fig. 3); unroll the hose quantity (7) that is necessary by
rotating the hose reel by means of the lever (3) (only EXTRA).
d) Unroll the high-pressure hose (24), connect the fast coupling connector to the water outlet
connector (6), screw and tighten (only CLASSIC) (operation C - Fig. 3).
e) Screw the end of the high-pressure pipe (7 or 24) (side without fast coupling for CLASSIC) on
the water gun thread (16) and tighten with two 17-mm box wrenches (not supplied). (operation
B - Fig. 3).
f) Insert the water suction filter (26) into the water suction connector and tighten it on the water
inlet connector of the water cleaner (see Fig. 1).
4.2 C
ONTROLS AND
WARNING
• The water supply must be able to guarantee the adequate delivery of water flow to the high
pressure cleaner; refer to the table of technical specifications.
In case of doubt, contact a Skilled Technician.
• Do not supply the water cleaner with water at a temperature in excess of 50°C/122°F or below
5°C/41°F.
• The pressure of the water supply must not be in excess of 8 bar/116 psi.
• Do not operate the high pressure cleaner with a priming depth in excess of 0 m / 0 ft.
• Do not operate the high pressure cleaner if it is not connected to a water supply.
• Do not supply the high pressure cleaner with salt water or water containing impurities. In this
event, run the high pressure cleaner for a few minutes with clean water.
fi«
CAUTION
• Follow current regulations for connection to the mains water supply in the country where the
water cleaner is installed.
4.3 C
C
HECKS AND
fi«
CAUTION
• A Skilled Technician must check that the electrical supply complies with the data indicated
on the identification label (12) on the high pressure cleaner. It is especially important that the
supply voltage does not differ more than +-5% from that indicated on the label.
• All connections to mains electricity must be carried out by a Qualified Eletrician according to
IEC 364 regulations or the equivalent standard in the country where the high pressure cleaner
is to be used. It is especially important that the current outlet where the high pressure cleaner is
connected is provided with an earth conductor and a suitable fuse (according to the size indicated
on the identification label and in the table of technical specifications), and must be protected by
a magneto-thermal differential circuit breaker, whose sensitivity is not in excess of 30 mA.
• If the power supply cable is too short, an extension cord can be used provided it is not longer
than 10 m / 32.8 ft, the section of the wires is at least 1.5mm² and the plug and the socket are
waterproof. Contact a Qualified Eletrician so that all these requirements are followed.
The use of unsuitable extension cords can be dangerous.
28
C

ONNECTION TO THE

ONNECTION TO THE
M
W
S
AINS
ATER
M
E
AINS
LECTRICITY
UPPLY
S
UPPLY

Werbung