UPS Monitoring

UPS monitoring is a standard feature of the AS/400 operating system. QUPSDLYTIM is a timer in the AS/400
that tells the system how long to run on UPS power before shutting down. Each AS/400 system is initially
assigned a default value for QUPSDLYTIM. Refer to the Uninterruptible Power Supply section in the IBM docu-
ment "AS/400 Advanced Series Backup and Recovery - Advanced," SC41-3305 (for AS/400 Models 2xx and
3xx), or "AS/400 Advanced Series Backup and Recovery - Advanced," SC41-4305 (for AS/400 Models 4xx and
5xx) for information on determining what this value is for your system, or for assistance in changing the value of
QUPSDLYTIM.
Caution:
*NOMAX tells the AS/400 to use customized shutdown software, and if none is available it
will immediately begin shutdown when utility power fails. Do not set QUPSDLYTIM to
"*NOMAX" unless you understand the implications of the *NOMAX function as described in
"AS/400 Advanced Series Backup and Recovery - Advanced," SC41-3305 (for AS/400 Models
2xx and 3xx), or "AS/400 Advanced Series Backup and Recovery - Advanced," SC41-4305
(for AS/400 Models 4xx and 5xx).