Removing the Existing Coiled Cord Cable

Procedure:
1 Rotate the locking collar at the base of the microphone in a counterclockwise direction until it stops.
2 Pull out the cord and away from the base of the microphone.
3 Install the new coiled cord GMKN4072_ in a reverse order of removal.
Part Number: GMKN4072_, Length: 65 cm (2.2 ft)

Figure 67: Pin Assignment of Cable from Accessory Connector to Microphone Housing

To Accessory Connector (left)
1
...
11
12
13
14
15
16
17
18
19
20
...
26

Radio-to-Data Device: Active Data Cable

The PMKN4104_ Active Data Cable provides a 5-wire RS232 interface (for example, RxD, TxD, CTS, RTS, DTR)
between a computer and a mobile radio. The cable has to be connected to the 26-pin Accessory Connector on the rear
side of the radio and into the 9-pin connector of a Data Device (for example, PC, Laptop, console). The PMKN4104_
Active Data Cable is not repairable. Order a replacement cable as necessary: Length: 2.0 m (6.56 ft).
Send Feedback
| |
nc
...
nc
GND (black)
EXT_MIC (blue)
nc
nc
nc
EXT_PTT (white)
nc
HOOK (red)
nc
...
nc
To Microphone Housing (right)
1
nc
2
nc
3
PTT (white)
4
EXT_MIC (blue)
5
GND (black)
6
HOOK (red)
7
nc
8
nc