Figure 13: Ethernet Cable (PMKN4141_, PMKN4140A_, PMKN4139_, PMKN4138_, PMKN4136_,
PMKN4146_)
1
Figure 14: Ethernet Cable PMKN4135_
1
Note: For PMKN4135_, the open-end wire for "CH" end shall be terminated with the in-box RJ50 plug
based on the "Ethernet Cable Pin Diagram". Use a 10P10C Crimping Tool to correctly crimp the RJ50 plug
to the open end of the cable, after it has been routed from the transceiver to the control head.
Number
1
2
Installing the Remote Mount Ethernet Control Head (eCH) onto the
Remote Mount Trunnion
When and where to use: Follow these steps to install the Remote Mount Enhanced Control Head onto the Remote
Mount Trunnion.
Procedure:
1 Slide the Remote Mount Enhanced Control Head onto the mounting trunnion until it snaps into place.
2 Tighten the screws at both sides of the trunnion. After a few turns, tilt the control head for an optimum view of the
display. Then, complete the tightening of the screws.
Description
EEH mark
CH mark
Note: Requires three (3) Ferrite
Clamps PN 91012044001. Manual
installation is required on all Ethernet
cables. Clamps are installed on the CH
end with 2-turns of wire around each
clamp.
Radio Installation | 57
2
2
Warning: Using the 'EEH'
and 'CH' marks ensure the
Ethernet Cables are connected
in the right way.
| |
Send Feedback