2. Safety

WARNING!
!
Before commissioning and opera ng, ensure that the approbriate temperature
calibrator has been selected in terms of temperature range, design and specific
measurement condi ons.
Further important safety instruc ons can be found in the individual chapters of
these opera ng instruc ons.

2.1 Intended use

The portable dry block temperature calibrators of the
calibra on of temperature sensors in laboratory, on board or in the field, in conformity with ISO
9001 standards. They offer automa c calibra on of thermostats with a simple func on, as well as
thermal tests on materials.
The dry block temperature calibrators are equipped with a temperature source and a built-in
reference temperature probe. If an unit under test is placed in a suitable drilling in the metal block
or insert, by comparison of the two measured values at any given temperature, a check of the
accurac and/or adjustment of the unit unter test can be carried out.
The dry block temperature calibrators of the
solely for the intended use described here, and may only be used accordingly.
The technical specifica ons in these opera ng instruc ons must be observed. Improper handling or
opera on of the instrument outside of its technical specifica ons requires the instrument to be
taken out of service immediately and inspected by an authorised DRUCK & TEMPERATUR
Leitenberger GmbH service engineer.
Handle this precision instrument with the required care (protect from humidity, impacts, strong
magne c fields, sta c electricity and extreme ambient temperature, do not insert any objects into
the instrument or its opening, except units under test (temperature probes) or external reference
probes into the suitable drillings in the well insert.
If the instrument is transported from a cold into a warm environment, the forma on of
condensa on may result in instrument malfunc on. Before pu ng it back into opera on, wait for
the instrument temperature and the room temperature to equalise.
Tel. +49 (0) 7121-90920-0 • Fax +49 (0) 7121-90920-99 •
DRUCK
&
TEMPERATUR
Leitenberger GmbH • Bahnhofstr. 33 • D-72138 Kirchentellinsfurt •
LR-Cal
PYROS
LR-Cal
PYROS
series have been designed and built
DT
-Info@Leitenberger.de •
30
series serve for the tes ng and
www.
LR
-Cal.net
• www.druck-temperatur.de
GERMANY

Werbung

Kapitel

Inhaltsverzeichnis
loading

Verwandte Produkte für LR-Cal PYROS 140-2L

Inhaltsverzeichnis