Herunterladen Inhalt Inhalt Diese Seite drucken

Operation; Operating Buttons; Status Indicators; Menu Items - EuroLite SPARK MASTER Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

The built-in control panel features four operating buttons and a display which shows all operation statuses of the
machine. The control panel allows the user to customize the DMX starting address and output height and switch
on/off the automatic stop of spark output in case of the device tipping over. The machine can be operated with the
wireless or cable remote control. Alternatively, it can be controlled with a DMX controller. DMX control will take
priority over the manual operation.

Operating buttons

Button
MENU
ENTER
UP / DOWN

Status indicators

Display
Heat
Ready
Wait
Clean

Menu items

Display
Addr DMX512
Volume Out
Tip Over
ON/OFF
Manual Test
Function
Selecting menu items
Activating spark output manually in "Manual Test" mode
Setting values
Function
The device is warming up
The device is ready for spark output
Awaiting next action / spark output disabled via DMX
Cleaning function via DMX active
Function
0-512
Adjusting the starting address
1-100%
Adjusting the fountain height
Activating or deactivating automatic stop of spark output in
case of the device tipping over by more than 45°
Note: The tipping sensor is a very important protection
mechanism. It should always be activated.
Manual activation of spark output for test purposes with
ENTER button