3
First Steps
3.2. Mechanical
connection
3.3. Electrical
connection

IO-Link interface

Connecting the
sensor hub
Connecting
sensors/actuators
www.balluff.com
BNI IOL-309/310-000-K024/K025:
The sensor hub modules require no separate supply voltage connection. Power is provided
through the IO-Link interface by the host IO-Link Master.
IO-Link is established by a 4 poles male.
Connection protection ground to FE terminal, if present.
Connect the incoming IO-Link line to the sensor hub.
Note
For the digital sensor inputs follow the input guideline per EN 61131-2, type 2.
Standard DIN rail mounting
Pin
24V
Power supply controller, +24V, max. 1.0A
Power supply output,
AUX
+24V, max. 1.6A
0V
GND references potential
IOL
C/Q, IO-Link Data transmission channel
Pin
Input: EN 61131-2, type: max. 30V
I/O
Output: max. 350mA
Total current all output max. 1.6A
24V
+24V, Total current max. 1A
GND
GND Reference potential