Herunterladen Inhalt Inhalt Diese Seite drucken

Dantherm CDT 30S MKII Serviceanleitung Seite 14

Vorschau ausblenden Andere Handbücher für CDT 30S MKII:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 107
User guide,
cont.
Error messages
An overview of possible errors which prevent normal operation
Yellow light on
centre LED with
emptying symbol
and FULL on display
Red light on right
warning LED HIGH
TEMP on display
Red light on right
warning LED AMBI-
ENT TEMP on
display
Red light on right
warning LED SEN-
SOR FAIL on
display. One of the
internal sensors is
defective. Use the
+/- keys to toggle
between 3 possible
errors
Red light on right
warning LED LP
STOP on display
12
Error message
Illustration
www.dantherm-ltd.ru • info@dantherm-ltd.ru • +7 (495) 545-48-79
Москва. Каширский проезд д. 19 стр. 2
Cause
Water container full
See guide below for emptying
Pressure or tem-
Check filter and dehumidifier
perature in high
for dirt in airways
pressure element
too high
Room temperature
Place the dehumidifier in the
out of normal range
specified temperature range,
between 3°-32°C
SENSOR FAIL
1: EVAP FAIL
Requires an authorised ser-
Evaporator
vice technician
thermometer
defective
2: COND FAIL
Requires an authorised ser-
Condenser
vice technician
thermometer
defective
3: ROOM FAIL The
Requires an authorised ser-
internal room
vice technician
thermometer is
defective
Leak in cooling
Requires an authorised ser-
circuit
vice technician
Remedy
Continued on next page

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Cdt 40s mkii

Inhaltsverzeichnis