Installing the infra-red receiver

The receiver (9) is to be fitted for preference on the clothes ca-
binet in such a way that the remote control can be pointed at
it without any hinderance (length of connection cable 3 m). If
necessary, a 3 metre cable extension can be supplied
(Part no. 40040-34800).
If it is not possible to instal the receiver beneath the wall
surface, on request Truma can provided a surface-moun-
ting frame (10 – Part no. 40000-52600) as a special accessory.
Drill a hole 55 mm in diameter. Lead the cable through from
behind and secure the receiver with 4 screws (11). Then attach
the cover frame (12), route the cable to the air conditioning
unit and connect to the unit at the side.
5 5
Ø
10
To round off the appearance of the cover frame, Truma
can provide side pieces (13) as special accessories in
8 different colours (please ask your dealer).
230 V electrical connection
and IR receiver connection
The electrical connection may only be carried out by a
qualified professional installer (in Germany, for example,
qualified in accordance with VDE 0100, Part 721). The instruc-
tions given here are not a challenge to the lay person to carry
out the electrical connection, but serve to provide additional
information for the professional fitter whom you engage!
Unscrew 2 screws (14) and open the cover of the electronic
system.
16
m
m
9
11
13
12
13
Insert mains cable plug (15) into socket. The plug is automati-
cally provided with strain relief by engaging in a retaining lug.
The retaining lug must be lifted with a screwdriver in order to
remove the plug from the socket.
Insert IR receiver plug into socket (16).
The connection (17) is needed if the Saphir vario air con-
ditioning unit is being operated via a Truma TG 1000 sinus
power inverter (COM connection/communication a or b).
Close electronic system cover again and screw the screws (14)
back in.
The cables must be long enough for the unit to be pulled out
of the false floor with the cables attached. All cables must be
secured with cable clips!
For maintenance or repair work, an isolating device must be
provided on the vehicle side to provide all-pole isolation from
the mains, with a contact interval of at least 3.5 mm.
Function test /
Mounting for the remote control
Position the mounting for the remote control as close as
possible to the receiver (9), in order to allow for the air-condi-
tioning system to be operated without removing the remote
control from its mounting.
In conclusion, all the functions of the device need to be tested
in accordance with the Operating Instructions.
The Operating Instructions and the completed guarantee card
are to be handed over to the vehicle owner.