For portable set-up:
Set up the pump on solid ground. When setting up in muddy or sandy ground the pump
should be operated while suspended in the medium, by a rope or chain, or placed on a
large baseplate. Do not suspend the pump by the cable.
For fixed installation:
Install the pump in compliance with DIN EN 12056-4 regulations (e.g. route the
discharge line with a loop above the locally defined backflow level).
FLOWTP30 with float switch:
For automatic cut-in/cut-out:
>
The cable is attached to the swivel clip at the end of the carrying handle.
>
Adjust the cut-in and cut-out level by varying the distance (the cable length) bet-
ween the swivel clip and the float switch. Define the cut-out level so that the pump
cannot run dry.
>
The float switch must be able to move without any hinderances and must not touch
the ground.
For control panel operation (Always-on):
>
Fit the "Always-on" clip (supplied as standard) by pressing it into the hole at the end
of the carrying handle above the swivel clip. Lock the float switch in the clip so that
it always points upwards (see page 25, figure 3).
>
The pump does not cut out and must be automatically protected from running dry.
FLOWTP30 OS without float switch:
For double switching operation (Always-on).