Carry the pump by the carrying handle only, not by the electrical connecting cable or
float switch. Do not bump or drop it. When lowering the pump into deep sumps or pits
use a rope or chain.
>
Observe the correct operating voltage (see "Technical data").
>
Never place the power plug in the water.
>
Connect the pump to properly installed sockets (in compliance with VDE and
power-supply company regulations) protected by at least 10 A (slow-blowing) fuses.
For submersible pumps of protection class I, all exposed conductive parts are
connected to the protective earth conductor. Before the pump is put into operation,
an electrically skilled person must check that the protective earth cable is properly
connected.
When operating pumps of protection class I, the following applies according to IEC
>
335-2-41:1984, Amendment 1:1990: Pumps of protection class I intended for use
in swimming pools or garden ponds must be equipped with a residual-current de-
vice (max. 30 mA) in the supply line. The pump may not be operated if any persons
are in the pool.
>
Temperatures higher than those permitted cause the pump to be shut off by the
temperature monitor. After the temperature monitor is triggered, disconnect the
pump from the electrical system before correcting the cause of the fault, as other-
wise it will switch on automatically once cooled down.

6. Transport

7. Electrical connection