Set up/installation

For portable set-up:
Set up the pump on solid ground. When setting up in muddy or sandy ground, the pump should be
operated while suspended in the medium, by a rope or chain, or be placed on a large base plate. Do not
suspend the pump by the cable.
For fixed installation:
Install the pump in compliance with DIN EN 12056-4 regulations (e.g. route the discharge line with a
loop above the locally defined backflow level).
FLOWTP30 with float switch
For automatic cut-in/cut-out:
/
The cable is attached to the swivel clip at the end of the carrying handle (see page 26, figure 3).
/
Adjust the cut-in and cut-out level by varying the distance (the cable length) between the
swivel clip and the float switch. Define the cut-out level so that the pump cannot run dry.
/
The float switch must be able to move without any hinderances and must not touch the
ground.
For control panel operation (Always-on):
/
Fit the "Always-on" clip (supplied as standard) by pressing it into the hole at the end of the
carrying handle above the swivel clip. Lock the float switch in the clip so that it always points
upwards (see page 26, figure 3).
/
The pump does not cut out and must be automatically protected from running dry.
FLOWTP30 OS without float switch
For double switching operation (Always-on).