Herunterladen Inhalt Inhalt Diese Seite drucken

Remote Controller Operation; Motion Sensor - Hitachi RCIM-1.0FSN4 Installations- Und Betriebshandbuch

Indoor units system free 4-way cassette
Vorschau ausblenden Andere Handbücher für RCIM-1.0FSN4:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 95

Remote controller operation

6 REMOTE CONTROLLER OPERATION
Refer to the Installation and Operation Manual of the remote control switch for details.

6.1 MOTION SENSOR

This setting is available only for the air panel with motion sensor
kit.

Function
The motion sensor detects a human activity by the change
of the infrared light.
This function saves the air conditioning capacity (adjusting
the set temperature, the air flow volume and the air flow
direction) automatically depending on a situation.
The operation after the motion sensor detects as absence
can be selected from "Running", "Stand-by" or "Stop" on the
remote control switch with the capacity saving.
?
N O T E
Do not use the motion sensor function when a baby or a handicapped
person stays by oneself. The motion sensor may detect as absence
and the operation may be stopped in the case of staying for long time
with a bit motion.
The motion sensor detects the human activity. However, if someone is
in a room with a bit motion, the motion sensor may detect as absence.
The motion sensor may detect as human activity if the indoor unit
with the motion sensor kit is installed near a moving object (ex. swing
operation of a heating appliance) which is difference in temperature
against atmosphere.
In the case that the indoor units are operated by 2 remote control
switches, the motion sensor setting is available only from the main
remote control switch.
The indoor unit operation can be stopped by the motion sensor
control.
?
N O T E
The indoor unit without the motion sensor kit and the indoor unit with
the motion sensor kit can be mixed to install. In this case, when the
operation is stopped by the motion sensor control, the indoor unit
without the motion sensor kit will also stop the operation.
While the air conditioning capacity is saved or the operation is
stopped by the motion sensor control, "Motion sensor is activated" is
displayed on LCD.
If the function "Prohibiting operation by remote control switch" is used
from the centralized controller, select the command "Running" or
"Stand-by" in "If absent" at the motion sensor control setting.
If "Stop" is selected, the motion sensor control can not be performed
correctly as follows:
- In the case that "Stop" is selected in the motion sensor control
setting and "Prohibiting operation by remote control switch"
(for all items) is set by the centralized controller, the operation
will not be stopped even if the motion sensor control function
changes to the stoppage condition.
- In the case that "Stop" is selected in the motion sensor control
setting and "Prohibiting operation by remote control switch" (for
part of items) is set by the centralized controller, the indoor unit
operation can not be restarted from the centralized controller
although the operation can be stopped under the stoppage
condition by the motion sensor control function.
6
PMML0363A rev.2 - 08/2016 - P5416559

Details for motion sensor control
The motion sensor control adjusts automatically the following
items depending on a situation.
Setting Temperature: The temperature is adjusted 1ºC or
2ºC for saving capacity.
Air Flow Volume: The air flow volume is adjusted to lower
one volume or to "Slo" (except during the dry operation).
Air Flow Direction: The air flow direction is adjusted to
horizontal.

Descriptions for setting items
Motion sensor setting
ON: The operating control function by the motion sensor is
activated.
OFF: The operating control function by the motion sensor is not
activated.
(The default setting is "ON".)
If absent
"If absent" is set for the indoor unit operation after the motion
sensor detects as absence for set time in "Check interval". The
operation can be selected from "Running", "Stand-by" or "Stop"
on the remote control switch.
(The default setting is "Running".)
Running:
The operation is continued with saving the capacity after
detected as an absence.
If the human activity is detected for a period of time, the
normal operation will be performed again.
Stand-by:
The operation mode is the fan operation at "Slo" speed.
If the human activity is detected for a period of time, the
normal operation will be performed again.
Stop:
The operation is stopped by the remote control switch when
all the indoor units with motion sensor kit detect absence
which are connected with same remote control switch.
If the human activity is detected for a period of time by the
stoppage, the normal operation is performed again.
Check Interval
When the motion sensor detects an absence at selected check
interval time, the function "If absent" will be executed. The
interval can be selected from 30, 60, 90 120 or 180. (The default
setting is 30 minutes)