6
Settings

Setting with the diagnosis terminal (keypad)

Possible settings with P2 "Speed"
With P2, a motor speed setpoint in percent of the rated speed in C00011 can be
preset in 10 steps (JOG fixed setpoint). The JOG setpoint is only activated if input
DI1 is set in "Local mode".
P2
Description
Motor speed in percent of the rated speed
setting C00011
Possible settings with P3 "Ramp"
P3
Description
Acceleration or deceleration time of the
motor in seconds
Possible settings with P1
Potentiometer P1 can be accessed after the cover has been removed. In order to
ensure the degree of protection of the controller, the cover has to be screwed in
again after the settings have been made.
During operation, P1 can be used to steplessly set the motor speed in percent of
the rated speed in C00011 if no JOG fixed setpoint P2 is active via DI1.
P1
Description
Motor speed in percent of the rated speed
C00011
6.2
Setting with the diagnosis terminal (keypad)
The controller can also be set and controlled with the diagnosis terminal. The
diagnosis terminal consists of a molded recess, connecting cable and the keypad
which cannot be directly plugged onto the controller. Descriptions for the
keypad can be done with the diagnosis terminal.
When the diagnosis terminal is connected, a preselected parameter is displayed
after initialisation. In the Lenze setting, the actual speed value (C00051) is
displayed. The preselected parameter can be changed (C00466).
58
0
1
2
[%]
0
11 22 33 44 55 66 77 88
0
1
2
[s]
0.1
0.5
1
0
[%]
0
l
EDK84DGDVBxxx4 DE/EN/FR/ES/IT 6.1
Setting
3
4
5
6
7
8
Setting
3
4
5
6
7
8
2
5
10 20 30 60 120
Setting
...
9
...
100
9
100
9

Werbung