This product is rated Medical Electrical equipment. EMC (Electromagnetic compatibility) is described in the
documentation included.
Installation and use of this product requires special precautions regarding EMC according to the EMC information.
Portable and mobile RF communications equipment can affect Medical Electrical equipment. Do not use RF equipment
near the product.
The use of ACCESSORIES such as handpieces and cables, other than those specified by the manufacturer, with
the exception of handpieces and cables sold by the manufacturer of this product as replacement parts for internal
components, may result in increased EMISSIONS or decreased IMMUNITY of this product.
Do not place this product adjacent to, or on top of, another device. This product and NSK Surgic Pro can however be
stacked for use with the NSK Link connection.
The system may present a possibility of malfunction when used in the presence of an electromagnetic interference
wave. Do not install the system in the vicinity of any device which emits magnetic waves. Turn OFF the Main Power
Switch of the system an ultrasonic oscillation device or an electrode knife is located close to the vicinity of use.
The handpiece may get hot when some types of tips are used at high power level or in an overloaded state. (The
temperature of the handpiece surface might exceed 41˚C.) If such abnormality is found, stop using for about 5 minutes
to allow the handpiece to cool.
Surface temperature of tip shall be more than 65 degree without using coolant water. To avoid this event, be sure to
use coolant water.
For added safety install the Control Unit in a place where the AC POWER Cord
can be easily removed. (It is possible to disconnect the control unit from the
power source by removing the AC POWER Cord.)
Grounding reliability can only be achieved when the equipment is connected to
an equipment receptacle marked "Hospital Only" or "Hospital Grade".
U.S. Federal law restricts this device to sale by or on the order of a licensed
physician.
No special training is required for this device.
The handpiece or handpiece cord during operation could interfere with computers, LAN cables in close vicinity, or
could cause noise in radio receivers nearby.
*Emission: Unnecessary energy generated by the device.
*Immunity: Tolerance to unnecessary energy received by the device.
NOTICE
3
Power plug below is used in North America area.
Plug Type NEMA 5-15P (Hospital Grade Type)