Controls

Fig. 8:
Front panel with controls
No.
Designation
Function
1
Service socket
Connection for electricity
consumer power supply.
2
Master switch
Lockable ON/OFF switch with
emergency stop function.
3
Setting-down but-
Extends the detent locks and sets
ton for runway
down the lifting platform. Press
and hold the button until both
detent locks engage in the snap
latches.
4
"Lower"
The selected lifting device moves
button
downward while the button is
pressed. Movement is stopped in
the following cases:
R Button is released.
R "Foot protection" safety lev-
R Lower end position is reached.
5
"Lift"
The selected lifting device moves
button
upward while the button is
pressed. Movement is stopped in
the following cases:
R Button is released.
R Upper limit value is reached.
Robert Bosch GmbH
el (200 mm) is reached.
Obligations of the plant operator | �LS ��4� | 29
�.��

Safety features

During assembly and operation, it must be ensured
that all safety devices are fully functional. This must
be verified on a regular basis and after any fault.
The lifting platform must only be maintained
and repaired by Bosch customer service or
an authorized service outlet with appropriate
certification.
Always use genuine replacement parts. The
installation of parts from other manufacturers will
render the type approval and any warranty claims
invalid.
In particular, the functioning of the following safety
devices must be checked after any fault.
Safety feature
Function
EMERGENCY
By way of the lockable yellow and red master
STOP
switch.
function
Deadman
The lifting (o) and lowering (u) functions are
control
only active while the corresponding buttons
are being pressed and held.
Foot protection
The lowering of the lifting platform is
function
stopped automatically at a height of 200 mm
("foot protection" safety level). In this case,
release the "Lower" button and check the
area under the lifting platform. If it is safe
to do so, press the "Lower" button again.
A warning signal sounds and the lifting
platform continues to move downward until
the lower end position is reached.
Synchronization
An electronic control system ensures that
control
the two runways are synchronized.
An electronic control system and monitoring
by a light barrier ensure that the two
runways are synchronized.
Overload
The drive motor is protected by a
protection for
temperature sensor. Following an overload,
drive motor
the lifting platform can be operated again
after a cooling time of 10 minutes.
Tab. 1:
Safety features