5. Measurement Functions and Ranges
Frequency Measuring
Range
5 Hz
50 Hz
500 Hz
5 kHz
- Sensitivity >3 V (Effective Value)
- Input Protection is 600 V DC or 600 V AC
Diode Test
Forward Current
0.3 mA
- Input Protection is 600 V DC or 600 V AC
- Off-Load Voltage: 1.5 V DC
Continuity Test
Test Current
0.3 mA
- Input Protection is 600 V DC or 600 V AC
Duty Cycle
Range
0.1 % - 99,9 %
- Pulse Width > 100µs, < 100 ms
- Frequency Range 5 Hz - 5 kHz
- Sensitivity > 3 V (Effective Value)
- Input Protection is 600 V DC or 600 V AC
Resolution
0.001 Hz
0.01 Hz
0.1 Hz
1 Hz
Resolution
1 mV
At resistances less than 150 Ohm
a signal sounds.
Resolution
0.1 %
47
Accuracy
± 1.5 % v. M. ±5 St.
Accuracy
± 10 % v. M. ±5 St.
Resistance
Accuracy
± 1.5 % v. M. ±5 St.